Abstract:Smoke bays in buildings are an important measure of fire smoke control. One fire compartment can be divided into various smoke bays. To figure out the rational division way with high safety, the influence of the smoke bay design on the fire safety was studied by using field model simulations to find the best method that ensures safety. The results show that smoke bays should be divided to match the evacuation exit distribution. The safety is seriously compromised if too many evacuation exits are connected to one smoke bay. The number of smoke bays should match the number of exits to improve fire safety.
王婉娣, 张辉. 建筑防烟分区划分安全性研究[J]. 清华大学学报(自然科学版), 2016, 56(12): 1297-1301,1311.
WANG Wandi, ZHANG Hui. Smoke bay design in buildings. Journal of Tsinghua University(Science and Technology), 2016, 56(12): 1297-1301,1311.
GB50016-2006. 建筑防火设计规范[S]. 北京:中国计划出版社, 2006.GB50016-2006. Code of Design on Building Fire Protection and Prevention[S]. Beijing:China Planning Press, 2006. (in Chinese)
[2]
GB50045-95. 高层民用建筑设计防火规范[S]. 北京:中国计划出版社, 2005.GB50045-95. Code for Fire Protection Design of Tall Buildings[S]. Beijing:China Planning Press, 2005. (in Chinese)
[3]
霍然, 胡源, 李元洲. 建筑火灾安全工程导论[M]. 合肥:中国科学技术大学出版社, 1999. HUO Ran, HU Yuan, LI Yuanzhou. Introduction to Building Fire Safety Engineering[M]. Hefei:University of Science and Technology of China Press, 1999. (in Chinese)
[4]
李引擎. 建筑防火性能化设计[M]. 北京:化学工业出版社, 2005.LI Yinqing. Performance-based Building Fire Protection Design[M]. Beijing:Chemical Industry Press, 2005. (in Chinese)
[5]
刘祥, 刘爽. 防烟分区划分的几点探讨[J]. 工程建设与设计, 2013(2):78-79.LIU Xiang, LIU Shuang. A discussion on the smoke zone[J]. Construction & Design for Project, 2013(2):78-79. (in Chinese)
[6]
吴文忠, 由世俊. 某地铁站台防烟分区存在问题分析[J]. 暖通空调, 2009(1):127-129.WU Wenzhong, YOU Shijun. Analysis of smoke control zoning for an underground railway platform[J]. Journal of HV& AC, 2009(1):127-129. (in Chinese)
[7]
Doheim R M, Yohanis Y G, Nadjai A, et al. The impact of atrium shape on natural smoke ventilation[J]. Fire Safety Journal, 2014, 63:9-16.
[8]
Chiu C, Chen C, Chen J, et al. Analyses of smoke management models in TFT-LCD cleanroom[J]. Building Simualtion, 2013, 6(4):403-413.
[9]
Tilley N, Rauwoens P, Fauconnier D, et al. On the extrapolation of CFD results for smoke and heat control in reduced-scale set-ups to full scale:Atrium configuration[J]. Fire Safety Journal, 2013, 59:160-165.
[10]
McGrattan K, Hostikka S, McDermott R, et al. Fire Dynamics Simulator User's Guide[R]. Washington DC, USA:National Institute of Standards and Technology (Special Publication 1019-6), 2013.
[11]
National Fire Protection Association. Standard for Smoke Management Systems in Malls, Atria and Large Areas[M]. Quincy MA, USA:National Fire Protection Association, 2009.
[12]
中华人民共和国公安部消防局. 中国消防手册[M]. 上海:上海科学技术出版社, 2010.The Fire Department of Ministry of Public Security of the People's Republic of China. China Fire Protection Handbook[M]. Shanghai:Shanghai Science and Technology Press, 2010. (in Chinese)