Please wait a minute...
 首页  期刊介绍 期刊订阅 联系我们
 
最新录用  |  预出版  |  当期目录  |  过刊浏览  |  阅读排行  |  下载排行  |  引用排行  |  百年期刊
Journal of Tsinghua University(Science and Technology)    2015, Vol. 55 Issue (6) : 691-694     DOI:
PHYSICS AND ENGINEERING PHYSICS |
Readout electronics for position sensitive boron coated straw detector
YU Hao1, GONG Hui1, WANG Yongqiang2, WANG Xuewu1, LI Jianmin1, LI Yuanjing1, KANG Kejun1
1. Key Laboratory of Particle and Radiation Imaging of the Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing 100084, China;
2. NUCTECH Company Limited, Beijing 100084, China
Download: PDF(1066 KB)  
Export: BibTeX | EndNote | Reference Manager | ProCite | RefWorks    
Abstract  Boron coated straw neutron detectors are being developed for use in the small-angle neutron scattering (SANS) instrument of the compact pulsed hadron source (CPHS) in Tsinghua University. This paper describes the readout electronics system for the position sensitive detector. The position resolution is estimated based on a noise analysis of the detector and the front end electronics. Then, the circuit parameters are optimized to improve the output signal characteristics. The position resolution of the detector and the readout electronics were evaluated using a charge injection test and a neutron beam test, with a position resolution of 2.7 mm in the charge injection test and 4.5 mm in the neutron beam test. The results that the detector and readout electronics meet the requirements for the neutron position measurement in the CPHS SANS instrument.
Keywords boron coated straw detector      readout electronics      position sensitivity      neutron detector     
ZTFLH:  TL822  
Issue Date: 15 June 2015
Service
E-mail this article
E-mail Alert
RSS
Articles by authors
YU Hao
GONG Hui
WANG Yongqiang
WANG Xuewu
LI Jianmin
LI Yuanjing
KANG Kejun
Cite this article:   
YU Hao,GONG Hui,WANG Yongqiang, et al. Readout electronics for position sensitive boron coated straw detector[J]. Journal of Tsinghua University(Science and Technology), 2015, 55(6): 691-694.
URL:  
http://jst.tsinghuajournals.com/EN/     OR     http://jst.tsinghuajournals.com/EN/Y2015/V55/I6/691
   
   
   
   
   
[1] Dana A, Daniel M. The Helium-3 shortage: Supply, demand, and options for congress [Z/OL]. (2010-12-22). http://fas.org/sgp/crs/misc/R41419.pdf.
url: http://fas.org/sgp/crs/misc/r41419.pdf.
[2] Lacy J L, Athanasiades A, Liang S, et al. Boron-coated straws as a replacement for 3He-based neutron detectors [J]. Nuclear Instruments and Methods in Physics Research Section A, 2011, 652: 359-363.
url: http://dx.doi.org/10.1016/j.nima.2010.09.011
[3] Nakamura T, Katagiri M, Toh K, et al. A position-sensitive tubular scintillator-based detector as an alternative to a 3He-gas-based detector for neutron-scattering instruments [J]. Nuclear Instruments and Methods in Physics Research Section A, 2014, 741: 42-46.
url: http://dx.doi.org/10.1016/j.nima.2013.12.043
[4] Richard T K, James H E, Luke E E, et al. Neutron detection alternatives to 3He for national security applications [J]. Nuclear Instruments and Methods in Physics Research Section A, 2010, 623: 1035-1045.
url: http://dx.doi.org/10.1016/j.nima.2010.08.021
[5] Lacy J L, Athanasiades A, Shehad N N, et al. Novel neutron detector for high rate imaging applications [C]//IEEE Nuclear Science Symposium Conference Record. Norfolk, USA: IEEE, 2002: 392-396.
[6] CHEN Cai, YANG Yigang, ZHU Shounuo, et al. Study of boron-lined straw-tube detector array for neutron scattering measurement [C]//IEEE Nuclear Science Symposium Conference Record. Anaheim, USA: IEEE, 2012: 176-179.
[7] HUANG Tuchen, GONG Hui, SHAO Beibei, et al. A prototype of the linear position-sensitive detectors for CPHS [J]. Physics Procedia, 2012, 26: 31-35.
url: http://dx.doi.org/10.1016/j.phpro.2012.03.005
[8] CHEN Cai, GONG Hui, YANG Yigang, et al. Realization and test of position sensitive boron coated straw-tube [C]//IEEE Nuclear Science Symposium Conference Record. Seoul, Korea: IEEE, 2013: 1-4.
[9] Esch P V, Gahl T, Guérard B. Design criteria for electronics for resistive charge division in thermal neutron detection [J]. Nuclear Instruments and Methods in Physics Research Section A, 2004, 526: 493-500.
url: http://dx.doi.org/10.1016/j.nima.2004.02.024
[10] Radeka V, Rehak P. Charge division mechanism on resistive electrode in position-sensitive detectors [J]. IEEE Transactions on Nuclear Science, 1979, 26(1): 225-238.
[11] 黄土琛, 宫辉, 邵贝贝. 位置灵敏3He管中子探测器前端电子学设计 [J]. 清华大学学报:自然科学版, 2012, 52(12):1731-1735.HUANG Tuchen, GONG Hui, SHAO Beibei. Design of the front-end electronics for linear position-sensitive 3He neutron detector [J]. Journal of Tsinghua University: Science and Technology, 2012, 52(12): 1731-1735. (in Chinese)
[12] Radeka V. Signal, noise and resolution in position-sensitive detectors [J]. IEEE Transactions on Nuclear Science, 1974, 21(1): 51-64.
[13] HUANG Tuchen, GONG Hui, SHAO Beibei, et al. Design of a new time-of-flight small-angle neutron scattering instrument at CPHS [J]. Physics Procedia, 2012, 26: 44-48.
url: http://dx.doi.org/10.1016/j.phpro.2012.03.007
[1] BAI Zhaole, ZHOU Qi, YANG Nan, LIU Feng, YANG Zhongjian, CHEN Baowei, WANG Jianlong. Scintillation neutron detectors based on a wavelength-shifting optical fiber using 232Th+ZnS(Ag)[J]. Journal of Tsinghua University(Science and Technology), 2018, 58(6): 558-562.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
Copyright © Journal of Tsinghua University(Science and Technology), All Rights Reserved.
Powered by Beijing Magtech Co. Ltd