海底沉管隧道位置特殊、结构狭长,一旦发生火灾,火焰和烟气会迅速蔓延扩散,可能对隧道结构造成破坏。因此,超宽断面沉管隧道结构的防护是海底沉管隧道火灾防控的关键。为了研究高压细水雾对超宽断面海底沉管隧道火灾的降温效果,搭建了横截面比例为1∶1的试验模型。其中,隧道的内径宽度为18.0 m、高度为6.6 m,长度为25.0 m。选取汽油为燃料,开展了高压细水雾作用下超宽断面沉管隧道火灾燃烧试验,对其燃烧行为、隧道顶棚下方温度演变规律以及高压细水雾降温冷却效果进行了研究。试验结果表明,热释放速率分别为2.5、5.0和10.0 MW时,最大火焰高度分别可达到约4.5、6.0和6.6 m;未喷放高压细水雾时,隧道顶棚下方最高温度分别约为180、310和528 ℃;开启喷雾后,3种工况下的隧道顶棚下方温度均能够有效降低至300 ℃以下,有效降低了火灾对隧道结构的破坏。基于上述研究结果为海底沉管隧道的火灾防控及灭火救援策略提供了建议。
Objective: Given the confined and elongated configuration of ultrawide subsea immersed tube tunnels, fires can lead to a rapid spread of flames and smoke, posing a substantial threat to the structural integrity of the tunnel and the safety of personnel. Traditional fire protection designs are often not ideal for cooling and controlling fires in such environments. Therefore, developing effective fire prevention and control technologies specifically suited to subsea tube tunnels is of great practical importance for ensuring tunnel safety and facilitating personnel evacuation. The main objective of this study is to evaluate the fire suppression and cooling effects of high-pressure mist in subsea immersed tube tunnels. To simulate real-life conditions, a full-scale 1:1 experimental model of a subsea tunnel was constructed, with the width, height, and length being 18.0, 6.6, and 25.0 m, respectively. This study aims to evaluate the combustion behavior, temperature distribution, and cooling efficiency of high-pressure water mist under different heat release rates. Methods: Gasoline was used as the fuel source in experiments conducted at three heat release rates: 2.5, 5.0, and 10.0 MW. Key parameters, including the flame height, temperature variation curves, and the cooling effects of high-pressure water mist, were measured throughout the experiments. The experimental setup was designed to closely replicate real fire scenarios in subsea tunnels, ensuring accurate and reproducible results. During the experiments, high-precision temperature sensors and imaging devices were used to continuously record and analyze the temperature distribution and flame characteristics. Results: The experimental results showed significant differences in the flame characteristics and temperature distribution across different heat release rates. For example, the maximum flame heights under 2.5, 5.0, and 10.0 MW heat release rates were 4.5, 6.0, and 6.6 m, respectively. Without high-pressure water mist for fire suppression, the highest ceiling temperatures reached 180℃, 310℃, and 528℃, respectively, posing a certain threat to the structural integrity of the tunnel. Upon activation of the high-pressure water mist, ceiling temperatures in all fire scenarios dropped significantly, falling below 300℃, thereby effectively reducing the risk of structural damage. Furthermore, for the 2.5 MW heat release rate, the activation of the high-pressure water mist rapidly reduced the temperature in the burning area to below 150℃. While complete suppression of flames was more challenging in higher-power fire scenarios, the water mist significantly lowered the ceiling temperature and the temperature in the burning area. This slowed the fire progression, providing valuable time for personnel evacuation and firefighting efforts. Conclusions: The experimental results confirm the effectiveness of high-pressure water mist in controlling fires within subsea immersed tube tunnels, particularly in reducing ceiling temperatures and minimizing structural damage risks. The use of high-pressure water mist in such tunnels can effectively reduce temperatures and mitigate the impact of fires on tunnel structures, providing technical support for improving fire safety. Overall, this research provides valuable insights for enhancing fire safety strategies in subsea immersed tube tunnels and provides practical recommendations for designing fire prevention and control systems.
ultrawide subsea immersed tube tunnels / fire experiment / high-pressure water mist / cooling effect
| 1 |
姚勇征. 受限出口边界下隧道火灾火行为和烟气输运规律研究[D]. 合肥: 中国科学技术大学, 2019.
YAO Y Z. Fire behaviors and smoke transportation law of tunnel fires under confined portal boundaries[D]. Hefei: University of Science and Technology of China, 2019. (in Chinese)
|
| 2 |
徐湃. 海底沉管隧道火灾烟气运动特性研究[D]. 重庆: 重庆交通大学, 2014.
XU P. Research on fire smoke movement characteristic in submarine immersed tunnel[D]. Chongqing: Chongqing Jiaotong University, 2014. (in Chinese)
|
| 3 |
蔡逸峰. 世界上最长的穿越海峡的隧道——青函隧道[J]. 交通与运输, 2008, 24 (1): 46- 47.
|
| 4 |
宋神友, 陈伟乐. 深中通道桥梁工程方案及主要创新技术[J]. 桥梁建设, 2021, 51 (5): 1- 7.
|
| 5 |
宋神友, 陈伟乐, 金文良, 等. 深中通道工程关键技术及挑战[J]. 隧道建设(中英文), 2020, 40 (1): 143- 152.
|
| 6 |
|
| 7 |
|
| 8 |
陈涛, 赵力增, 张少禹, 等. 我国长大海底隧道关键消防技术问题研究[J]. 消防科学与技术, 2017, 36 (10): 1394- 1398.
|
| 9 |
|
| 10 |
|
| 11 |
|
| 12 |
|
| 13 |
|
| 14 |
姚坚, 朱合华, 闫治国. 隧道结构防火保护措施现状及评析[J]. 地下空间与工程学报, 2007, 3 (4): 732-736, 741.
|
| 15 |
郭军, 刘帅, 蒋树屏. 海底隧道管节结构防火试验与数值模拟[J]. 中国公路学报, 2016, 29 (1): 96-104, 114.
|
| 16 |
|
| 17 |
|
| 18 |
|
| 19 |
|
| 20 |
张培红, 许文斌, 曹宇. 通风与细水雾耦合灭火机理实验研究[J]. 消防科学与技术, 2017, 36 (7): 959- 962.
|
| 21 |
田向亮, 钟茂华, 刘畅, 等. 细水雾抑制隧道甲醇火灾的全尺寸实验研究[J]. 火灾科学, 2019, 28 (1): 35- 41.
|
| 22 |
|
| 23 |
陈越, 陈伟乐, 宋神友, 等. 深中通道沉管隧道主要建造技术[J]. 隧道建设(中英文), 2020, 40 (4): 603- 610.
|
| 24 |
金文良, 宋神友, 陈伟乐, 等. 深中通道钢壳混凝土沉管隧道总体设计综述[J]. 中国港湾建设, 2021, 41 (3): 35- 40.
|
| 25 |
|
| 26 |
李振兴. 基于CFD模拟分析的大断面公路隧道汽车火灾烟气特性研究[D]. 上海: 同济大学, 2008.
LI Z X. CFD based simulation analysis on research of smoke features of vehicle fire in large cross-section road tunnel[D]. Shanghai: Tongji University, 2008. (in Chinese)
|
| 27 |
|
| 28 |
|
| 29 |
INGASON H. Design fires in tunnels[C]//MOLAG M. Proceedings of the Second International Symposium Safe & Reliable Tunnels, Innovative European Achievements. Lausanne, Switzerland: IEA, 2006: 1-11.
|
| 30 |
房玉东. 细水雾与火灾烟气相互作用的模拟研究[D]. 合肥: 中国科学技术大学, 2006.
FANG Y D. Study on interaction of water mist with fire smoke[D]. Hefei: University of Science and Technology of China, 2006. (in Chinese)
|
| 31 |
王亚琼, 李培军, 任锐, 等. 细水雾和纵向通风耦合作用对隧道火灾影响的数值模拟[J]. 重庆交通大学学报(自然科学版), 2022, 41 (8): 43- 52.
|
/
| 〈 |
|
〉 |