Combustion behavior and temperature distribution of dual-source fire with different lateral offset distances in tunnels

CHEN Rongfang, GUO Zhiguo, LIU Zuwen, ZHOU Lingjian, YANG Yurun, TAN Qinglan

Journal of Tsinghua University(Science and Technology) ›› 2024, Vol. 64 ›› Issue (9) : 1608-1616.

PDF(9050 KB)
PDF(9050 KB)
Journal of Tsinghua University(Science and Technology) ›› 2024, Vol. 64 ›› Issue (9) : 1608-1616. DOI: 10.16511/j.cnki.qhdxxb.2024.22.007
PUBLIC SAFETY

Combustion behavior and temperature distribution of dual-source fire with different lateral offset distances in tunnels

  • {{article.zuoZhe_EN}}
Author information +
History +

Abstract

[Objective] Multisource fire accidents frequently occur in tunnels, and their combustion characteristics are complex, influenced by both the parameters of the source itself and air entrainment and thermal feedback of adjacent fire sources. The combustion characteristics of multisource fires are related to the size, fuel type, and spacing of neighboring sources. In a dual-source fire in a tunnel, adjacent dual sources may compete for air, leading to flame merging. During flame merging, special flame phenomena occur, such as flying fire and fire whirlwinds, increasing the probability of fire spread and the degree of danger. Thus, building a reduced-size tunnel model to systematically analyze the evolution mechanism of multisource fire behavior is necessary. [Methods] Herein, we built a 1∶6-scaled tunnel model and conducted scaled experiments to investigate the dynamic evolution characteristics of restricted symmetric dual-source fire in natural ventilation tunnels under different fire source spacings. We studied the combustion rate, flame morphology, flame fusion, and ceiling temperature distribution. In particular, the ceiling temperature was further divided into near- and far-fire-source regions. We aimed to reveal the evolution of an asymmetric entrainment mechanism involving flame tilting and the fusion of a restricted symmetric dual-source fire in a tunnel. In addition, we constructed a quantitative model for the highest temperature rise of symmetrical dual-source fires under different fire source spacings and lateral offset distances. Thus, the dynamic characteristics of the tilting or even fusion of a restricted symmetric dual-source fire were elucidated. [Results] This study found that the mass loss rate, heat release rate, and flame height of the fuel were negatively correlated with the lateral offset distance and fire source spacing. When the dimensionless distance between the fire sources (S/D) was less than or equal to 1, flame fusion occurred, and a peak temperature occurred below the ceiling. As the distance between fire sources increased, the maximum temperature distribution transitioned from a “single peak” to a “double peak”. When the S/D≥4, the two fire sources essentially burned independently, and the peak number of the maximum temperature curve changed to 2. The dimensionless maximum temperature rise in the near-fire-source region exhibited an exponential decay relationship with the dimensionless lateral offset distance. A prediction model for the maximum temperature rise in the near-fire-source region was established and verified through comparison with experimental data from previous study and this study and numerical simulation results. [Conclusions] This study provides basic data to further elucidate the combustion mechanism of dual-source fire in tunnels under different lateral offset distances. Moreover, this study offers a theoretical basis for smoke control and emergency rescue during multisource fires in tunnels.

Key words

tunnel fire / dual-source fire / lateral offset / combustion behavior / temperature distribution

Cite this article

Download Citations
CHEN Rongfang, GUO Zhiguo, LIU Zuwen, ZHOU Lingjian, YANG Yurun, TAN Qinglan. Combustion behavior and temperature distribution of dual-source fire with different lateral offset distances in tunnels[J]. Journal of Tsinghua University(Science and Technology). 2024, 64(9): 1608-1616 https://doi.org/10.16511/j.cnki.qhdxxb.2024.22.007

References

[1] LIN C L, CHIEN C F. Lessons learned from critical accidental fires in tunnels[J]. Tunnelling and Underground Space Technology, 2021, 113:103944.
[2] WEI S Q, WAN H X, ZHOU X H, et al. Experimental study on flame tilt angles of two unequal fires in a longitudinal ventilated tunnel[J]. Tunnelling and Underground Space Technology, 2023, 137:105125.
[3] THOMAS P H, BALDWIN R, HESELDEN A J M. Buoyant diffusion flames:Some measurements of air entrainment, heat transfer, and flame merging[J]. Symposium (International) on Combustion, 1965, 10(1):983-996.
[4] BALDWIN R. Flame merging in multiple fires[J]. Combustion and Flame, 1968, 12(4):318-324.
[5] MENG N, SHU Y M, ZHANG S H. Study on smoke temperature induced by two fires in a naturally ventilated tunnel[J]. Tunnelling and Underground Space Technology, 2023, 131:104774.
[6] HOTTEL H C. Certain laws governing the diffusive burning of liquids:A review[J]. Fire Research Abstracts and Reviews, 1959, 1:41-44.
[7] 刘畅,钟茂华,林鹏,等.水利水电工程分岔型隧道全尺寸火灾实验研究[J].清华大学学报(自然科学版), 2022, 62(1):1-12. LIU C, ZHONG M H, LIN P, et al. Full-scale experimental study of a bifurcated tunnel fire in a hydropower engineering project[J]. Journal of Tsinghua University (Science&Technology), 2022, 62(1):1-12.(in Chinese)
[8] HEIDARINEJAD G, MAPAR M, PASDARSHAHRI H. A comprehensive study of two fire sources in a road tunnel:Considering different arrangement of obstacles[J]. Tun-nelling and Underground Space Technology, 2016, 59:91-99.
[9] WANG Q, WANG S M, LIU H, et al. Characterization of ceiling smoke temperature profile and maximum temperature rise induced by double fires in a natural ventilation tunnel[J]. Tunnelling and Underground Space Technology, 2020, 96:103233.
[10] HE K, CHENG X D, LI Y Z, et al. Experimental study on flame characteristics of double fires in a naturally ventilated tunnel:Flame merging, flame tilt angle and flame height[J]. Tunnelling and Underground Space Technology, 2021, 114:103912.
[11] HANSEN R, INGASON H. Model scale fire experiments in a model tunnel with wooden pallets at varying distances[R]. Västerås, Sweden:Mälardalen University, 2010.
[12] HANSEN R, INGASON H. Heat release rates of multiple objects at varying distances[J]. Fire Safety Journal, 2012, 52:1-10.
[13] ZHOU Y, CHEN F, GENG Z Y, et al. Experimental study on the characteristics of temperature distribution of two pool fires with different transverse locations in a naturally ventilated tunnel[J]. Tunnelling and Underground Space Technology, 2021, 116:104095.
[14] JI J, WAN H X, GAO Z H, et al. Experimental study on flame merging behaviors from two pool fires along the longitudinal centerline of model tunnel with natural ventilation[J]. Combustion and Flame, 2016, 173:307-318.
[15] 邓磊.隧道内多火源相互作用燃烧行为及排烟控制研究[D].合肥:合肥工业大学, 2021. DENG L. Study on interaction combustion behavior and smoke exhaust control of multiple fire sources in tunnels[D]. Hefei:Hefei University of Technology, 2021.(in Chinese)
[16] 孙建春.考虑列车阻塞效应及火源位置条件下长大铁路隧道火灾烟气特性研究[D].成都:西南交通大学, 2019. SUN J C. Study on the fire smoke characteristics of long railway tunnel under consideration of train blockage effect and fire source location[D]. Chengdu:Southwest Jiaotong University, 2019.(in Chinese)
[17] ZHONG W, LI Z Z, WANG T, et al. Experimental study on the influence of different transverse fire locations on the critical longitudinal ventilation velocity in tunnel fires[J]. Fire Technology, 2015, 51(5):1217-1230.
[18] LI Y Z, LEI B, INGASON H. The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires[J]. Fire Safety Journal, 2011, 46(4):204-210.
PDF(9050 KB)

Accesses

Citation

Detail

Sections
Recommended

/