PDF(1756 KB)
Optimization design of zero-frequency anti-vibration device for overhead line
Junhui LI, Bin ZHAO, Peng LI, Zepeng SUN, Zhao ZHANG, Chang LIU
Journal of Tsinghua University(Science and Technology) ›› 2026, Vol. 66 ›› Issue (7) : 1434-1441.
PDF(1756 KB)
PDF(1756 KB)
Optimization design of zero-frequency anti-vibration device for overhead line
Objective: Persistent strong aeolian vibrations in recent years have caused multiple conductor and strand breakages, as well as hardware wear and failure, across long-span and standard-span transmission lines throughout northwestern, northern, and northeastern China. To address the limitations of existing vibration dampers, specifically their suboptimal damping characteristics and restricted protection spans, this study develops an optimized design that effectively mitigates these fatigue risks. By enhancing the aeolian-vibration resistance of transmission lines, this approach protects conductors and fittings, thereby extending their service lives. Methods: A nonlinear energy sink method was used to optimize traditional vibration-damper designs, after which the vibration-mitigation performances of engineering prototypes were experimentally verified and theoretically evaluated. First, a theoretical nonlinear coupling model was established to analyze the vertical coupling vibration between the conductor and the nonlinear-stiffness damper, incorporating the damping, mass, and cubic stiffness of the oscillator. Next, nonlinear dynamic methods were used to decouple and solve the model. Thereafter, the numerical relationship between the displacement function and strain of the conductor and damper oscillator was clarified to maximize the proportion of oscillator vibration energy to the total energy of the coupled system. Based on this design, three critical coefficients were optimized and selected: the mass, nonlinear stiffness, and damping of the oscillator system. Results: The theoretical analysis indicated that the impact of the mass factor of the vibration-isolation device (oscillator) on the maximum dynamic bending strain of the conductor was negligible under low-intensity aeolian vibration. Conversely, the stiffness factor significantly impacted performance, necessitating rigorous analysis and optimization before structural design in transmission engineering. Furthermore, enhancing the damping characteristics was essential for effective vibration mitigation. Second, following authoritative industry testing standards, engineering prototypes of the nonlinear-stiffness damper were designed and customized using a 140 m experimental line as a typical example and experimental object. Comparative experiments were conducted to evaluate key performance indicators, including power characteristics and protection spans, thereby validating the optimization principles of the nonlinear stiffness and damping parameters. The related indicators, such as resonance frequency dispersion, maximum peak-to-valley ratio, and the effective damping frequency range, satisfied all standard engineering requirements, demonstrating that the device was suitable for deployment and applications on operational transmission lines. Finally, based on the power characteristics and anti vibration effect evaluation experiments in the existing standards, the data showed that the damping ratio of a single nonlinear-stiffness damper, which was greater than or equal to 1.5, represented a 140.0% increase over traditional FR-type anti-vibration hammers adapted to the same conductor model. Under identical strain-control thresholds, the optimized nonlinear-stiffness damper achieved a maximum protection span of 402 m, compared with 280 m by a traditional damper, representing a significant 43.6% increase. Conclusions: Overall, this study verified the effectiveness and technical advantages of the proposed design, demonstrating that the engineering application of the nonlinear energy sink theory significantly enhances aeolian-vibration resistance for high-voltage transmission lines.
transmission lines / wind resistance performance / nonlinear energy sink / anti-vibration device / cubic stiffness
| 1 |
栗婧, 方琦钰, 关城, 等. 电网应急预案领域本体模型构建及应用[J]. 清华大学学报(自然科学版), 2025, 65(6): 1079- 1089.
|
| 2 |
张佳庆, 孙韬, 蒋弘瑞, 等. 基于林火风险的高压输电线路无人机巡检路径规划[J]. 清华大学学报(自然科学版), 2024, 64(5): 911- 921.
|
| 3 |
曹云昊. 输电线路微风振动锁定现象机理研究[D]. 保定: 华北电力大学, 2024.
CAO Y H. Research on the mechanism of lock-in phenomenon in aeolian vibration of transmission lines[D]. Baoding: School of Energy Power and Mechanical Engineer, 2024. (in Chinese)
|
| 4 |
冯砚厅, 李文彬, 李金奎, 等. 输电线路预绞式防振锤对导线磨损机理及预防措施研究[J]. 电网与清洁能源, 2021, 37(3): 24- 30.
|
| 5 |
胥明凯, 朱坤双, 李元良, 等. 电力作业多源要素风险的自适应识别模型[J]. 清华大学学报(自然科学版), 2024, 64(6): 1047- 1059.
|
| 6 |
张维兴. 非线性能量阱的若干关键问题研究[D]. 天津: 天津理工大学, 2021.
ZHANG W X. Research on some key problems of nonlinear energy sink[D]. Tianjin: Tianjin University of Technology, 2021. (in Chinese)
|
| 7 |
|
| 8 |
|
| 9 |
|
| 10 |
郑智伟, 黄修长, 华宏星, 等. 非线性能量阱的曲梁设计研究[J]. 振动与冲击, 2024, 43(22): 53- 61.
|
| 11 |
张治力. 加装非线性隔震装置的变压器抗震分析与样机仿真研究[D]. 哈尔滨: 哈尔滨工业大学, 2017.
ZHANG Z L. Anti-seismic analysis and virtual prototype simulation on transformer with nonlinear isolation device[D]. Harbin: Harbin Institute of Technology, 2017. (in Chinese)
|
| 12 |
|
| 13 |
|
| 14 |
|
| 15 |
赵彬, 李孟轩, 刘彬, 等. 含有阻尼颗粒的零频防舞器试验研究[J]. 高电压技术, 2024, 50(4): 1518- 1525.
|
| 16 |
国家能源局. 防振锤技术条件和试验方法: DL/T 1099—2021[S]. 北京: 中国电力出版社, 2021.
National Energy Administration. Technical requirements and tests for damper: DL/T 1099—2021[S]. Beijing: China Electric Power Press, 2021. (in Chinese)
|
/
| 〈 |
|
〉 |