Readout electronics for position sensitive boron coated straw detector

YU Hao, GONG Hui, WANG Yongqiang, WANG Xuewu, LI Jianmin, LI Yuanjing, KANG Kejun

Journal of Tsinghua University(Science and Technology) ›› 2015, Vol. 55 ›› Issue (6) : 691-694.

PDF(1066 KB)
PDF(1066 KB)
Journal of Tsinghua University(Science and Technology) ›› 2015, Vol. 55 ›› Issue (6) : 691-694.
PHYSICS AND ENGINEERING PHYSICS

Readout electronics for position sensitive boron coated straw detector

  • {{article.zuoZhe_EN}}
Author information +
History +

Abstract

Boron coated straw neutron detectors are being developed for use in the small-angle neutron scattering (SANS) instrument of the compact pulsed hadron source (CPHS) in Tsinghua University. This paper describes the readout electronics system for the position sensitive detector. The position resolution is estimated based on a noise analysis of the detector and the front end electronics. Then, the circuit parameters are optimized to improve the output signal characteristics. The position resolution of the detector and the readout electronics were evaluated using a charge injection test and a neutron beam test, with a position resolution of 2.7 mm in the charge injection test and 4.5 mm in the neutron beam test. The results that the detector and readout electronics meet the requirements for the neutron position measurement in the CPHS SANS instrument.

Key words

boron coated straw detector / readout electronics / position sensitivity / neutron detector

Cite this article

Download Citations
YU Hao, GONG Hui, WANG Yongqiang, WANG Xuewu, LI Jianmin, LI Yuanjing, KANG Kejun. Readout electronics for position sensitive boron coated straw detector[J]. Journal of Tsinghua University(Science and Technology). 2015, 55(6): 691-694

References

[1] Dana A, Daniel M. The Helium-3 shortage: Supply, demand, and options for congress [Z/OL]. (2010-12-22). http://fas.org/sgp/crs/misc/R41419.pdf.
[2] Lacy J L, Athanasiades A, Liang S, et al. Boron-coated straws as a replacement for 3He-based neutron detectors [J]. Nuclear Instruments and Methods in Physics Research Section A, 2011, 652: 359-363.
[3] Nakamura T, Katagiri M, Toh K, et al. A position-sensitive tubular scintillator-based detector as an alternative to a 3He-gas-based detector for neutron-scattering instruments [J]. Nuclear Instruments and Methods in Physics Research Section A, 2014, 741: 42-46.
[4] Richard T K, James H E, Luke E E, et al. Neutron detection alternatives to 3He for national security applications [J]. Nuclear Instruments and Methods in Physics Research Section A, 2010, 623: 1035-1045.
[5] Lacy J L, Athanasiades A, Shehad N N, et al. Novel neutron detector for high rate imaging applications [C]//IEEE Nuclear Science Symposium Conference Record. Norfolk, USA: IEEE, 2002: 392-396.
[6] CHEN Cai, YANG Yigang, ZHU Shounuo, et al. Study of boron-lined straw-tube detector array for neutron scattering measurement [C]//IEEE Nuclear Science Symposium Conference Record. Anaheim, USA: IEEE, 2012: 176-179.
[7] HUANG Tuchen, GONG Hui, SHAO Beibei, et al. A prototype of the linear position-sensitive detectors for CPHS [J]. Physics Procedia, 2012, 26: 31-35.
[8] CHEN Cai, GONG Hui, YANG Yigang, et al. Realization and test of position sensitive boron coated straw-tube [C]//IEEE Nuclear Science Symposium Conference Record. Seoul, Korea: IEEE, 2013: 1-4.
[9] Esch P V, Gahl T, Guérard B. Design criteria for electronics for resistive charge division in thermal neutron detection [J]. Nuclear Instruments and Methods in Physics Research Section A, 2004, 526: 493-500.
[10] Radeka V, Rehak P. Charge division mechanism on resistive electrode in position-sensitive detectors [J]. IEEE Transactions on Nuclear Science, 1979, 26(1): 225-238.
[11] 黄土琛, 宫辉, 邵贝贝. 位置灵敏3He管中子探测器前端电子学设计 [J]. 清华大学学报:自然科学版, 2012, 52(12):1731-1735.HUANG Tuchen, GONG Hui, SHAO Beibei. Design of the front-end electronics for linear position-sensitive 3He neutron detector [J]. Journal of Tsinghua University: Science and Technology, 2012, 52(12): 1731-1735. (in Chinese)
[12] Radeka V. Signal, noise and resolution in position-sensitive detectors [J]. IEEE Transactions on Nuclear Science, 1974, 21(1): 51-64.
[13] HUANG Tuchen, GONG Hui, SHAO Beibei, et al. Design of a new time-of-flight small-angle neutron scattering instrument at CPHS [J]. Physics Procedia, 2012, 26: 44-48.
PDF(1066 KB)

Accesses

Citation

Detail

Sections
Recommended

/