[1] YANG H, LIU G Q, ZHANG L F, et al. Defect diagnosis methods and development trend for grounding grid[J]. Advanced Technology of Electrical Engineering and Energy, 2016, 35(10): 35-42. (in Chinese) 杨虹, 刘国强, 张来福, 等. 电力系统接地网缺陷诊断方法及发展趋势[J]. 电工电能新技术, 2016, 35(10): 35-42.
[2] WANG S, ZHANG B, ZHANG J, et al. Measurement method of impulse grounding impedance of grounding device[J]. Power System Technology, 2019, 43(1): 356-362. (in Chinese) 王森, 张波, 张健, 等. 接地装置冲击接地电阻测试方法[J]. 电网技术, 2019, 43(1): 356-362.
[3] XU Y Q, YANG H, LI P. Earth fault analysis on low resistance grounded distribution network with inverter interfaced distribution generation[J]. Electrical Measurement & Instrumentation, 2018, 55(16): 57-63, 71. (in Chinese) 徐玉琴, 杨浩, 李鹏. 含逆变型分布式电源的小电阻接地方式配电网单相接地故障分析[J]. 电测与仪表, 2018, 55(16): 57-63, 71.
[4] CHEN J W, QIAN Z H, ZHU L W, et al. Application of electrochemical noise to soil corrosion monitoring of grounding grid[J]. Corrosion & Protection, 2016, 37(5): 371-374. (in Chinese) 陈建伟, 钱洲亥, 祝郦伟, 等. 电化学噪声在接地网土壤腐蚀监控中的应用[J]. 腐蚀与防护, 2016, 37(5): 371-374.
[5] MA G, JIANG L R, XU G C. Study on corrosion fault diagnosis for grounding grid based on the Tellegen's Theorem[J]. Electrical Measurement & Instrumentation, 2016, 53(22): 91-95. (in Chinese) 马刚, 蒋林洳, 徐谷超. 基于特勒根定理的接地网腐蚀诊断研究[J]. 电测与仪表, 2016, 53(22): 91-95.
[6] ZHONG Q. Research on non-destructive testing of grounding grids in substations using ultrasonic guided waves[D]. Beijing: Beijing University of Technology, 2012. (in Chinese) 钟茜. 电力系统扁钢超声导波无损评价方法研究[D]. 北京: 北京工业大学, 2012.
[7] SHI H, WANG F H, HU X M, et al. Experimental studies on substation grounding grid fault diagnosis using electromagnetic diagnosis method[J]. Electrical Measurement & Instrumentation, 2018, 55(16): 6-12. (in Chinese) 施会, 王丰华, 胡徐铭, 等. 变电站接地网电磁诊断法的试验研究[J]. 电测与仪表, 2018, 55(16): 6-12.
[8] KOU X K, ZHANG K, ZHANG S Y, et al. Study on grounding grid connective resistance of large-scale substation[J]. Power System Technology, 2008, 32(2): 88-92. (in Chinese) 寇晓, 张科, 张嵩阳, 等. 大型变电站接地网导通状况研究[J]. 电网技术, 2008, 32(2): 88-92.
[9] ZENG L, LUO Z, LIN J, et al. Excitation of Lamb waves over a large frequency-thickness product range for corrosion detection[J]. Smart Materials and Structures, 2017, 26(9): 095012.
[10] WANG Z, HUANG S L, WANG S, et al. Compressed sensing method for health monitoring of pipelines based on guided wave inspection[J]. IEEE Transactions on Instrumentation and Measurement, 2020, 69(7): 4722-4731.
[11] SEN D, AGHAZADEH A, MOUSAVI A, et al. Data-driven semi-supervised and supervised learning algorithms for health monitoring of pipes[J]. Mechanical Systems and Signal Processing, 2019, 131: 524-537.
[12] HUANG S L, WANG Z, WANG S, et al. Review on advances of pipe electromagnetic ultrasonic guided waves technology and its application[J]. Chinese Journal of Scientific Instrument, 2018, 39(3): 1-12. (in Chinese) 黄松岭, 王哲, 王珅, 等. 管道电磁超声导波技术及其应用研究进展[J]. 仪器仪表学报, 2018, 39(3): 1-12.
[13] RIBICHINI R, CEGLA F, NAGY P B, et al. Study and comparison of different EMAT configurations for SH wave inspection[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2011, 58(12): 2571-2581.
[14] ZHANG C, LIU S Z, YANG Q X, et al. Experiment of crack detection of metal plate based on electromagnetically induced acoustic emission[J]. Advanced Technology of Electrical Engineering and Energy, 2011, 30(1): 84-88. (in Chinese) 张闯, 刘素贞, 杨庆新, 等. 基于电磁声发射的金属板裂纹检测实验研究[J]. 电工电能新技术, 2011, 30(1): 84-88.
[15] WANG Z, HUANG S L, WANG S, et al. Multifrequency identification and exploitation in lamb wave inspection[J]. IEEE Access, 2019, 7: 150435-150443.
[16] LEE J S, KIM Y Y, CHO S H. Beam-focused shear-horizontal wave generation in a plate by a circular magnetostrictive patch transducer employing a planar solenoid array[J]. Smart Materials and Structures, 2008, 18(1): 015009.
[17] ARUN K, DHAYALAN R, BALASUBRAMANIAM K, et al. An EMAT-based shear horizontal (SH) wave technique for adhesive bond inspection[J]. AIP Conference Proceedings, 2012, 1430(1): 1268-1275.
[18] WU J J, TANG Z F, YANG K J, et al. Signal strength enhancement of magnetostrictive patch transducers for guided wave inspection by magnetic circuit optimization[J]. Applied Sciences, 2019, 9(7): 1477.
[19] SEUNG H M, PARK C I, KIM Y Y. An omnidirectional shear-horizontal guided wave EMAT for a metallic plate[J]. Ultrasonics, 2016, 69: 58-66.
[20] SEUNG H M, KIM Y Y. Generation of omni-directional shear-horizontal waves in a ferromagnetic plate by a magnetostrictive patch transducer[J]. NDT & E International, 2016, 80: 6-14.
[21] WANG Z, HUANG S L, WANG S, et al. A damage localization method with multimodal lamb wave based on adaptive polynomial chirplet transform[J]. IEEE Transactions on Instrumentation and Measurement, 2020, 69(10): 8076-8087.
[22] ZHU X J, HAN Z D, DU D, et al. Imaging and inspection of ultrasonic SH guided wave by synthetic aperture focusing[J]. Journal of Tsinghua University (Science and Technology), 2011, 51(5): 687-692. (in Chinese) 朱新杰, 韩赞东, 都东, 等. 基于合成孔径聚焦的超声SH导波成像检测[J]. 清华大学学报(自然科学版), 2011, 51(5): 687-692.
[23] ZHANG Y, HUANG S L, ZHAO W, et al. Mode recognition of lamb wave testing signals of metal plate's defects based on STFT[J]. Electrical Measurement & Instrumentation, 2015, 52(4): 19-23. (in Chinese) 张宇, 黄松岭, 赵伟, 等. 基于STFT的金属板缺陷兰姆波检测信号模式识别[J]. 电测与仪表, 2015, 52(4): 19-23.
[24] LI F C, MENG G. Dispersion analysis of Lamb waves with narrow frequency bands[J]. Acta Physica Sinica, 2008, 57(7): 4265-4272. (in Chinese) 李富才, 孟光. 窄频带Lamb波频散特性研究[J]. 物理学报, 2008, 57(7): 4265-4272.
[25] ROSTAMI J, CHEN J M, TSE P W. A signal processing approach with a smooth empirical mode decomposition to reveal hidden trace of corrosion in highly contaminated guided wave signals for concrete-covered pipes[J]. Sensors, 2017, 17(2): 302.
[26] WANG P, ZHOU W S, LI H. A singular value decomposition-based guided wave array signal processing approach for weak signals with low signal-to-noise ratios[J]. Mechanical Systems and Signal Processing, 2020, 141: 106450.
[27] WANG Z, HUANG S L, WANG Q, et al. A new time-of-flight extraction method for narrowband Lamb wave in metallic plate[J]. The Applied Computational Electromagnetics Society Journal, 2019, 34(6): 985-990.
[28] DAI D Y, HE Q B. Structure damage localization with ultrasonic guided waves based on a time-frequency method[J]. Signal Processing, 2014, 96: 21-28.
[29] NURMALIA, NAKAMURA N, OGI H, et al. Mode conversion behavior of SH guided wave in a tapered plate[J]. NDT & E International, 2012, 45(1): 156-161.
[30] WANG S, HUANG S L, WANG Q, et al. Mode identification of broadband Lamb wave signal with squeezed wavelet transform[J]. Applied Acoustics, 2017, 125: 91-101.